Size and Weight Specifications:
Group Size – 31
Nominal Voltage - 24v
Fully Charged Battery Voltage 27.5v
Weight - 25.3 lbs
Length - 13"
Width - 6.75"
Height - 8.5"
Discharge Specifications:
Continuous Discharge Current - 60A
C.C.A Current - 240A at 6sec Burst
BMS Discharge Current Cut-Off - 100A
Prefer Low Voltage Disconnect - 24V
Max Charge - 27.5V
BMS Discharge Voltage Cut-Off - 24.5V
Reconnect Voltage - 24.9V
Short Circuit Protection - 200-600 µs
Technology Specifications:
Usable Capacity (AH) - 50AH
Depth of Discharge - >99% DOD
Reserve Minutes @ 20A - 300 min
Reserve Minutes @ 50A - 120 min
Self Discharge - <2% per month
Modular - Series or Parallel Connection
Up To 4 in 1 Bank